1 point

It could be, depending on where you land on the DIY vs building code spectrum… Also what your local building code details in terms of low voltage cable.

In my experience unless you’re intentionally going through air handling ductwork, CMG is fine, though I would go with CMR at least, just as a matter of safety. I have yet to see a residential home with any fire protection or fire breaks, at all, nevermind where you would think to put them, like between floors and whatnot. The homes in my area are mostly built from timber, so we’re basically living inside a framework of dried out wood, so putting a fire break between wood framed floors where the floor/ceiling shares a set of wooden cross members for support, seems like it would be unnecessary, since the framing of the building is going to conduct the fire between levels.

Ethernet is low voltage, so it’s largely unregulated. The only real regulation is regarding plenum or riser spaces, and the latter is mostly when floors are intentionally or naturally separated in terms of shared fate when it comes to fire. I only see fire breaks in concrete structures, usually apartments or commercial buildings.

YMMV, not every country has the same building codes, so every person reading this will need to do their own research or pay someone who knows.

My point remains, regardless of all this conjecture: even if it’s $2000 or more, this is structure cabling that should service the premise for as long as it continues to stand, which is hopefully many decades. Over 20 years, at $2000 for installation, you’re looking at a cost of around $8.34/mo for the cabling to exist.

Considering people will pay 10x that for Internet service, and the addition of Ethernet in the building will allow them to take full advantage of the internet they’re paying for, I’d call that a bargain.

permalink
report
parent
reply
1 point

You will generally run into fire stops in the framing, like you can see here:

https://www.oneprojectcloser.com/fire-stops-fire-blocking-in-studs/

When I ran wires to my office, I had to cut out one section of drywall above it, another below it, and then use a right angle attachment for my drill to go through it. Pull wire through and seal it with fire block foam.

permalink
report
parent
reply
1 point

Seems pointless considering the fire stop is made from something flammable.

permalink
report
parent
reply
1 point

Its purpose is to slow it down, not stop it. There would be a chimney effect where smoke rises out of the channel and fresh oxygen is allowed to come in from below. The blocks here prevent that from happening.

permalink
report
parent
reply

memes

!memes@lemmy.world

Create post

Community rules

1. Be civil

No trolling, bigotry or other insulting / annoying behaviour

2. No politics

This is non-politics community. For political memes please go to !politicalmemes@lemmy.world

3. No recent reposts

Check for reposts when posting a meme, you can only repost after 1 month

4. No bots

No bots without the express approval of the mods or the admins

5. No Spam/Ads

No advertisements or spam. This is an instance rule and the only way to live.

Sister communities

Community stats

  • 12K

    Monthly active users

  • 2.7K

    Posts

  • 53K

    Comments