Darn it, I checked the spelling a few times before I hit space. Must have changed it afterwards. I’ll leave it. 😂

permalink
report
parent
reply

For those that don’t know what deluding is:

Delidding removes the integrated heat spreader (IHS) on the processor so that you can directly attach a water block to it for more efficient cooling. This practice is widespread among enthusiasts and overclockers, as they could get the most performance out of these chips and break world records.

permalink
report
reply

I see someone mention watchtower, while not a bad thing, I just prefer to manually update. This helps to ensure any breaking changes don’t break my system. Especially with something like Immich at it’s had a lot of them recently as they work towards stable. I just generally subscribe to their release and do updates as necessary.

permalink
report
parent
reply

Now that you mention it, I always do a

docker system prune -f

This will clean up old images that are no longer used. I setup an alias command in Linux to do all of those commands.

I just named it docker_update and saved it in my ~/.bashrc

permalink
report
parent
reply

Did you use docker compose file or just run a command to start the container?

Edit: I always use compose files. For that you can do the following:

docker compose pull
docker compose down
docker compose up -d

You don’t technically need the stop, but I’ve found once or twice in the past where it was good to stop because of image dependencies that I forgot to put in my compose.

For running a command directly I found this website that seems to summarize it pretty well I think:

https://www.cherryservers.com/blog/how-to-update-docker-image

permalink
report
parent
reply

I’m sure you’ve done this, but you’ll want to make sure you’re using all of the water being input based on calculations.

For instance, if you’re making 100 m3/min and you need 400 m3/min for 100%. Then you’ll need to limit fresh intake to 300 m3/min. However, if your refineries aren’t running at 100% and maybe only using 300 m3/min then your waste won’t be used to full capacity.

To counter this I tend to starve the system of water by limiting fresh and then bumping it up until max is reached.

It’s a bit finicky, but seems to work for me.

permalink
report
parent
reply

I use a valve on waste water to prevent back flow, but not limit the output. Then I put a valve on fresh water to limit its input to the amount needed minus waste water output. It does take a little to get up to 100%, but I haven’t had any issues lately.

permalink
report
reply

I wonder if making a blueprint for the floors would be easy enough. Might make the whole thing a lot quicker.

permalink
report
parent
reply

I’m pretty sure they just need the Rockwell Retro Encabulator to reduce that side fumbling.

permalink
report
parent
reply

Not OP, but it kind of looks like our Cavachon.