To start off: I was explaining to my friend that I don’t have a grounding point in my house (plumbing is PVC, outlets are gcfi protected only, not allowed to drive a grounding rod into the ground, etc…) and that I’ve just been handling sensitive electronics with just luck and preparation (humidity, moisturizer, no synthetic clothing, etc…) all this time. He told me to just wire myself to a good, multimeter tested, grounding point in a car and that will discharge any built-up static electricity. I’m not smart enough to argue with him on this subject but that doesnt seem the safest. Would that work or should I just keep doing my method? My understanding is that chassis grounding is essentially replacing wires with the frame so the outcome would just be connecting myself to the negative terminal of a car battery.
Tldr: I’m explaining my lack of a grounding point at home for sensitive electronics and is advised by my friend to wire myself to a grounded point in a car to discharge built-up static electricity. However, I’m uncertain about the safety of this suggestion and questions whether my current method of handling electronics with precautions is sufficient.
Edit: lmao people are really getting hung up on the no grounded outlet part. Umm my best explanation I guess is that its an older house that had 2 prong outlets and was “updated” with gfci protected outlets afterwards think the breakers as well. My understanding is that its up to code but I’m not an electrician. As for the plumbing I’m sure there’s still copper somewhere but the majority has been updated to pvc over the years. Again it’s not my house I don’t want to go biting the hand that feeds me. Thank you though, haha
Edit #2: thank you all so much for the helpful advice, I really appreciate all of you!
Edit: I jumped over a detail in my memory. The ground pin goes to neutral in the breaker box and neutral is grounded. The key part is that the ground pin isn’t an isolated circuit that just goes to the dirt. I’ll leave the below so you can see what people were correctly arguing with me about.
The ground pin in a north American outlet, at least, isn’t actually grounded. It’s just a dedicated circuit that goes back to the neutral line in the circuit breaker box. It doesn’t go to the ground there, either. Not to mention you don’t get static sparks when touching dirt anyway because ground is a terrible conductor anyway - it works on a power delivery scale because it’s effectively infinitely big. These things only vaguely work for static reduction by being large metal structures that can sink the excess static. That’s why doorknobs and coat racks happily shock you.
No, the “ground” in a car is not actually a ground at all. It’s a chassis common power point. Ground is the entirely wrong term but people will argue it up and down because it has always been called ground. Mixups in function like this are exactly why I’ll argue to use the right terminology. Common supplies power by chassis. Ground sinks stray power away from the device/fingers (hence why I don’t argue against calling a house ground a ground).