“never plug extension cords into extension cords” is probably the most common piece of electrical related advice I’ve ever heard. But if you have, say, 2 x 2m long extension cords, and you plug one into the other, why is that considered a lot more unsafe than just using a single 4 or 5 meter cord?

Does it just boil down to that extra connection creating another opportunity for the prongs to slip out and cause a spark or short circuit? Or is there something else happening there?

For that matter - why aren’t super long extension cords (50 or more meters) considered unsafe? Does that also just come down to a matter of only having 2 connections versus 4 or more on a daisy chained cord?

Followup stupid question: is whatever causes piggybacked extension cords to be considered unsafe actually that dangerous, or is it the sort of thing that gets parroted around and misconstrued/blown out of proportion? On a scale from “smoking 20 packs of cigarettes a day” to “stubbing your toe on a really heavy piece of furniture”, how dangerous would you subjectively rate daisy chaining extension cords, assuming it was only 1 hop (2 extension cords, no more), and was kept under 5 or 10 metres?

I’m sure there’s probably somebody bashing their head against a wall at these questions, but I’m not trying to be ignorant, I’m just curious. Thank you for tolerating my stupid questions

You are viewing a single thread.
View all comments
37 points
*

Others have pretty much mentioned it. Too thin of conductors for the total length required which can overload the cable and heat it up. If you’re just charging your phone it’s unlikely to cause a problem but the more amps you pull the riskier it gets.

Here’s a helpful chart…

Edit: Even at harbor freight (cheap hardware store) a 50ft 12 gauge extension cord is about $40 and weighs 7 pounds.

permalink
report
reply
25 points

lol “gauge”

americans will use anything except the metric system

permalink
report
parent
reply
12 points

I’ve always found gauge to be especially odd, because the number gets smaller as you go bigger, so at one point you can’t go any further even though you can go fatter.

permalink
report
parent
reply
10 points

Oh, you can get bigger! Just keep adding 0s. It’s fine.

permalink
report
parent
reply
14 points
*

16 AWG – 1.3 mm^2
14 AWG – 2 mm^2
12 AWG – 3.3 mm^2
10 AWG – 5.2 mm^2

For us from the civilised part of the world ;-)

However, as in Europe we have 230 V system, approximately half the cross section, as stated in the table above, is sufficient.

Edit: This is how the above text should be displayed:

permalink
report
parent
reply
1 point

Both are measurements of cross-sectional AREA and are defined in terms of square millimeters (mm^2), not mm.

permalink
report
parent
reply
3 points

What is the metric unit for cables?

permalink
report
parent
reply
3 points

for cross-sectional area? mm2.

permalink
report
parent
reply
3 points
*
Removed by mod
permalink
report
parent
reply
5 points

Is it just me or is anyone else perturbed that the cable sizes in this infographic are all the same gauge?

permalink
report
parent
reply
1 point

Do you just mean the art showing them as the same size? Because that’s common in a lot of infovraphics to not be to scale if they are clearly labeled

permalink
report
parent
reply
5 points

the cable sizes in this infographic are all the same gauge?

They’re not. They are clearly marked as different gauges, except the left most two which have different plug types… one is two prong, the other is three prong.

permalink
report
parent
reply
4 points

a 50ft 12 gauge extension cord is about $40

$40USD would be $58CAD.

A 50-ft 12-gauge extension cord costs $112+ CAD anywhere in Canada. A 100-ft is $200+ CAD. Like… fffffuuuuuck.

permalink
report
parent
reply
2 points
*

Space heater is “medium duty” while a router is “heavy duty”?

permalink
report
parent
reply
15 points

This is also known as a router

permalink
report
parent
reply
2 points

Oohkay.

permalink
report
parent
reply
7 points

router as in ‘tool for finer details in woodworking.’ most router motors can spin at 10000rpm at their lowest and anything with a motor, by definition, uses more power than something without a motor

permalink
report
parent
reply
1 point
Deleted by creator
permalink
report
parent
reply
-11 points

It doesn’t make sense. Temperature difference does not depends on length.

permalink
report
parent
reply
19 points

Adding length creates more resistance which creates more heat. Thinner conductors can’t handle it as well.

permalink
report
parent
reply
-8 points
*

And more surface area for heat dissipation. https://lemm.ee/comment/17115060

They cancel out.

permalink
report
parent
reply

No Stupid Questions

!nostupidquestions@lemmy.world

Create post

No such thing. Ask away!

!nostupidquestions is a community dedicated to being helpful and answering each others’ questions on various topics.

The rules for posting and commenting, besides the rules defined here for lemmy.world, are as follows:

Rules (interactive)


Rule 1- All posts must be legitimate questions. All post titles must include a question.

All posts must be legitimate questions, and all post titles must include a question. Questions that are joke or trolling questions, memes, song lyrics as title, etc. are not allowed here. See Rule 6 for all exceptions.



Rule 2- Your question subject cannot be illegal or NSFW material.

Your question subject cannot be illegal or NSFW material. You will be warned first, banned second.



Rule 3- Do not seek mental, medical and professional help here.

Do not seek mental, medical and professional help here. Breaking this rule will not get you or your post removed, but it will put you at risk, and possibly in danger.



Rule 4- No self promotion or upvote-farming of any kind.

That’s it.



Rule 5- No baiting or sealioning or promoting an agenda.

Questions which, instead of being of an innocuous nature, are specifically intended (based on reports and in the opinion of our crack moderation team) to bait users into ideological wars on charged political topics will be removed and the authors warned - or banned - depending on severity.



Rule 6- Regarding META posts and joke questions.

Provided it is about the community itself, you may post non-question posts using the [META] tag on your post title.

On fridays, you are allowed to post meme and troll questions, on the condition that it’s in text format only, and conforms with our other rules. These posts MUST include the [NSQ Friday] tag in their title.

If you post a serious question on friday and are looking only for legitimate answers, then please include the [Serious] tag on your post. Irrelevant replies will then be removed by moderators.



Rule 7- You can't intentionally annoy, mock, or harass other members.

If you intentionally annoy, mock, harass, or discriminate against any individual member, you will be removed.

Likewise, if you are a member, sympathiser or a resemblant of a movement that is known to largely hate, mock, discriminate against, and/or want to take lives of a group of people, and you were provably vocal about your hate, then you will be banned on sight.



Rule 8- All comments should try to stay relevant to their parent content.

Rule 9- Reposts from other platforms are not allowed.

Let everyone have their own content.



Rule 10- Majority of bots aren't allowed to participate here.

Credits

Our breathtaking icon was bestowed upon us by @Cevilia!

The greatest banner of all time: by @TheOneWithTheHair!

Community stats

  • 8.8K

    Monthly active users

  • 1.9K

    Posts

  • 50K

    Comments