“never plug extension cords into extension cords” is probably the most common piece of electrical related advice I’ve ever heard. But if you have, say, 2 x 2m long extension cords, and you plug one into the other, why is that considered a lot more unsafe than just using a single 4 or 5 meter cord?
Does it just boil down to that extra connection creating another opportunity for the prongs to slip out and cause a spark or short circuit? Or is there something else happening there?
For that matter - why aren’t super long extension cords (50 or more meters) considered unsafe? Does that also just come down to a matter of only having 2 connections versus 4 or more on a daisy chained cord?
Followup stupid question: is whatever causes piggybacked extension cords to be considered unsafe actually that dangerous, or is it the sort of thing that gets parroted around and misconstrued/blown out of proportion? On a scale from “smoking 20 packs of cigarettes a day” to “stubbing your toe on a really heavy piece of furniture”, how dangerous would you subjectively rate daisy chaining extension cords, assuming it was only 1 hop (2 extension cords, no more), and was kept under 5 or 10 metres?
I’m sure there’s probably somebody bashing their head against a wall at these questions, but I’m not trying to be ignorant, I’m just curious. Thank you for tolerating my stupid questions
But unless coiled up on the ground the longer cable also has more area to dissipate heat, so the longer cable doesn’t change anything here. The heat output will be consistent for any section of the cable no matter how much more cable there is on easier side of it.
The only think that the different resistance would affect is the voltage drop to the end device. But voltage drop varies wildly so you are unlikely to have a meaningful difference caused by a few extension cords (unless maybe you are already a bad case like an apartment building to start).
Resistance of a cable is (resistivity x Length)/(πr^2) so the residence increases with length, which is why longer extension cords are designed thicker to reduce resistance. Power grids are voltage stabilized so the voltage drop will be negligible but it will take more power to get down the daisy chain, producing more heat.
The longer wire (being also thicker) has less resistance and is therefore wasting less power as heat, that’s where the Voltage drop is going.
Sure, most of the time it’s fine if you know what you’re doing, but that’s why it’s general wisdom and not a hard rule, like “don’t put metal in the microwave”, it’s said to protect those that have no idea what they’re doing/why the saying exists